Items | Method | Condition | Unit |
Direction |
Typical Value |
Dielectric Constant, Dk | IPC-TM-650 2.5.5.5 | C-24/23/50, 10GHz | - | Z | 3.30±0.05 |
Dielectric Constant, Dk | IPC-TM-650 2.5.5.15 | C-24/23/50, 10GHz | - | X/Y | 3.56±0.05 |
Dissipation Factor, Df | IPC-TM-650 2.5.5.15 | C-24/23/50, 10GHz | - | X/Y | 0.0030 |
Thermal Coefficient of Dk | IPC-TM-650 2.5.5.5 | -55 to 85℃ | ppm/℃ | Z | +50 |
PIM |
43dBM
1900MHz
|
50 ohm
0.0307"
|
dBc | -158 | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | COND A | MΩ·cm | 6.8 x 108 | |
Surface Resistivity | IPC-TM-650 2.5.17.1 | COND A | MΩ | 5.3 x 107 | |
Flexual Strength | IPC-TM-650 2.4.4 | R.T. | MPa | X/Y | 200/160 |
CTE | IPC-TM-650 2.4.24 | 50~260℃ | ppm/℃ | Z | 55 |
IPC-TM-650 2.4.41 | 50~260℃ | ppm/℃ | X/Y | 12/12 | |
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | >280 | |
Td | IPC-TM-650 2.4.24.6 | TGA (5% wt. loss) | ℃ | 400 | |
Thermal Conductivity | ASTM D5470 | 50℃ | W/(m·k) | Z | 0.65 |
Water Absorption | IPC-TM-650 2.6.2.1 | D-24/23 | % | 0.05 | |
Peel Strength (1oz HVLP) | IPC-TM-650 2.4.8 | 288℃/10s | N/mm [lb/in] | 1.05 [6.0] | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 |
Remarks:
1. All the typical value is based on the 0.780(0.0307") thickness specimen, but not guarantee data.
2. All the typical values listed above are for your reference only and not intended for specification. Please contact Shengyi Technology Co., Ltd. for detailed information. All rights from this data sheet are reserved by Shengyi Technology Co., Ltd.
Explanation: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning